Measures Temperature & Humidity
Stores 10,000 measured values, 13,000 data points (RMS-MLOG-B)
Fail-safe, thanks to internal battery
3 years battery lifetime
Compatible with RMS Gateway, RMS server software and RMS Cloud
Conforms to FDA 21 CFR Part 11 / GAMP5.
Measures Temperature & Humidity
Stores 10,000 measured values, 13,000 data points (RMS-MLOG-B)
Fail-safe, thanks to internal battery
3 years battery lifetime
Compatible with RMS Gateway, RMS server software and RMS Cloud
Conforms to FDA 21 CFR Part 11 / GAMP5.
Measures Temperature & Humidity
Stores 20,000 data points
Measurement range: -10…50 °C and 0…100 %RH
Accuracy: ±0.8 %rh @ 10...60 %rh / ±0.3 K and ±1.3 %rh @ 60...100 %rh / ±0.3 K
Measures Temperature & Humidity
Stores 20,000 data points
Measurement range: -10…50 °C and 0…100 %RH
Accuracy: ±0.8 %rh @ 10...60 %rh / ±0.3 K and ±1.3 %rh @ 60...100 %rh / ±0.3 K
Features:
Measurement ranges -110 up to +20°Cdp
Dew point or ppmV moisture content output
Accuracy ±2 °Cdp
Traceable calibration certificate
Easidew I.S. IECEx, cQPSus, ATEX and UKCA approvals
Low cost of ownership and easy maintenance with sensor exchange program
316 Stainless steel sensor and sample blocks ...
Features:
Measurement ranges -110 up to +20°Cdp
Dew point or ppmV moisture content output
Accuracy ±2 °Cdp
Traceable calibration certificate
Easidew I.S. IECEx, cQPSus, ATEX and UKCA approvals
Low cost of ownership and easy maintenance with sensor exchange program
316 Stainless steel sensor and sample blocks ...
Features
Repeatedly fast measurements at low pressure from less than 15 minutes for T95 to -60 °C (-76 °F)
Higher pressure measurements possible – up to 350 barg (5076 psig)
Long battery life: up to 48 hours of typical use between charges
Intuitive application kits allow quick and straightforward connection to your sample...
Features
Repeatedly fast measurements at low pressure from less than 15 minutes for T95 to -60 °C (-76 °F)
Higher pressure measurements possible – up to 350 barg (5076 psig)
Long battery life: up to 48 hours of typical use between charges
Intuitive application kits allow quick and straightforward connection to your sample...
Features
New chilled mirror hybrid sensor gives fast dynamic response to changes in humidity
Accurate to ±0.15°C dew point, ±0.1°C temperature
Wide measurement range from -40 to +120°C dew point
Choice of communication methods, including Modbus TCP over Ethernet communication for easy networking
Optional pressure...
Features
New chilled mirror hybrid sensor gives fast dynamic response to changes in humidity
Accurate to ±0.15°C dew point, ±0.1°C temperature
Wide measurement range from -40 to +120°C dew point
Choice of communication methods, including Modbus TCP over Ethernet communication for easy networking
Optional pressure...