High-speed bar graph & Cont. buzzer with LED
Specifications:
|
CD732
|
Measuring range
|
Best accuracy
|
Resolution
|
Input impedance
|
|
DCV |
600m/6/60/600/1000V |
±(0.5%+2) |
0.1mV |
10M~100MΩ |
|
ACV |
6/60/600/750V |
±(1.2%+5) |
0.001V |
10M~11MΩ |
|
DCA |
600μ/6000μ/60m/600m/6/15A |
±(1.5%+3) |
0.1μA |
|
|
ACA |
600μ/6000μ/60m/600m/6/15A |
±(1.8%+5) |
0.1μA |
|
|
Resistance |
600/6k/60k/600k/6M/60M |
±(1.2%+4) |
0.1Ω |
|
|
Capacitance |
40n/400n/4μ/40μ/400μ/4000μ |
±(5.0%+6) |
0.01nF |
|
|
Frequency |
9.999/99.99/999.9/9.999k/99.99k |
±(0.5%+3) |
0.001Hz |
|
|
Duty cycle |
20~80% |
±(0.5%+5) |
|
|
|
Continuity |
Buzzer sounds and LED lights up at between 10Ω~60Ω Open voltage:approx.0.63V |
|||
|
Diode test |
Open voltage:approx.2.7V |
|||
|
Display |
numeral display 6000 |
|
Sampling rate |
3 times/sec., 30 times/sec.,for bar graph |
|
Bandwidth |
45~500Hz |
|
Fuse |
0.4A/1000V 30kA Φ6.3×32mm |
|
Battery |
R6(1.5V)x2 |
|
Battery life |
Approx.400h (manganese battery) at DCV range |
|
Size/Mass |
H167×W90×D48mm/320g(including holster) |
|
Safety standard |
IEC61010 CAT.Ⅲ600V/CAT.Ⅱ 1000V |