World of test and calibration
World of test and calibration
CAT.IV, AC current measurable max. 1000A.
Specifications
Function | Measuring range | Best accuracy | Resolution |
---|---|---|---|
ACA | 60.00/600.0/1000A | ±(2.5%+5) | 0.01A |
ACV | 6.000/60.00/600.0/1000V | ±(1.5%+3) | 0.001V |
DCV | 6.000/60.00/600.0/1000V | ±(1%+3) | 0.001V |
Resistance | 6.000k/60.00k/600.0k/6.000M/60.00MΩ | ±(2%+5) | 0.001kΩ |
Frequency | ACV 10Hz-10kHz, ACA 10Hz-2kHz | ±(1%+5) | 0.1Hz |
Capacitance | 60.00n/600.0n/6.000µ/60.00µ/600.0µ/6.000m/60.00mF | ±(4%+3) | 0.01nF |
Continuity | Buzzer sounds below 30Ω Open voltage: approx. 1V or less | ||
Detection of Electricity | Buzzer sounds, "-" is shown on LCD, and LED flickers Detects ACV and EF of approx. 90V or more (50/60Hz) |
Sampling rate | Approx. 3 times/sec. |
Bandwidth | ACA 45-400Hz ACV 45Hz-1kHz |
Display | 6000/9999(Hz function) |
Clamp diameter/Conductor size | Φ34mm/10×64mm |
Battery | LR03×3 |
Battery life | Approx. 200 hrs. |
Size/Mass | H252×W85×D40mm/Approx. 360g |
Safety standards | IEC61010 CAT.Ⅳ600V/CAT.Ⅲ1000V |
Data sheet
Specific References